International Equipments
Home / Material Testing Equipments / Melt Flow Index Tester (MFI)
ASTM D1238 · ISO 1133 · IS 2530 — MFR · MVR · Melt Density

Melt Flow Index Tester (MFI)

A high-precision Melt Flow Index Tester range — manual, auto-cut and fully computerized models — measuring the melt flow rate (MFR), melt volume rate (MVR) and melt density of thermoplastics to ASTM D1238 and ISO 1133.

  • Four models — from economical manual to fully computerized (Method A & B)
  • Ambient to 400 °C, 0.1 °C resolution, ±0.1 °C accuracy, auto-tuned PID
  • Hard chrome plated test loads: 1.2, 2.16, 3.8, 5, 10 & 21.6 kg
  • Tests HDPE, LDPE, PP, PVC, PET, ABS, PC, Nylon and most thermoplastics
Made in IndiaISO 9001:2015CE CertifiedExported to 60+ countries
Overview

The most important QC test in the polymer industry

A Melt Flow Index Tester — also called an MFI tester, melt indexer or extrusion plastometer — measures the flow rate of a molten thermoplastic through a standard orifice under a set temperature and load. The result, in grams per 10 minutes, is one of the most important quality parameters in the plastic and polymer industry.

MFI values let manufacturers identify a polymer grade, confirm batch-to-batch consistency, check the effect of additives and verify that incoming raw material matches specification before production. International Equipments manufactures a complete range in Mumbai and exports to 60+ countries, from entry-level manual models to fully computerized testers that calculate MFR, MVR and melt density automatically.

Our Range

Four models for every lab and budget

From an economical manual tester to a fully automatic Method A & B instrument — each links to full specifications.

How the test works

Step by step

  1. Set temperature & loadSelect the ASTM/ISO test temperature and standard weight for your polymer and let the barrel stabilise.
  2. Charge the barrelLoad the pre-weighed polymer, compact it and preheat for the specified time.
  3. Apply the weightPlace the load; the molten polymer extrudes through the standard orifice.
  4. Cut & measureMethod A — cut the extrudate at fixed intervals and weigh each cut. Method B — a displacement sensor tracks piston travel for MVR & melt density.
  5. Calculate the resultMFR (g/10 min), MVR (cc/10 min) and melt density are computed, and on computerized models stored, averaged and reported.
Technical Specifications

Melt Flow Index Tester (MFI) specifications

Specifications shared across the range; automation level varies by model (see Our Range above).

StandardsASTM D1238, ISO 1133; IS 2530, IS 10810
Temperature rangeAmbient to 400 °C
Temperature resolution0.1 °C
Temperature accuracy±0.1 °C
ControllerMicroprocessor auto-tuned PID
Test loads1.2, 2.16, 3.8, 5, 10 & 21.6 kg (hard chrome plated)
Orifice & pistonHardened, to ASTM D1238 / ISO 1133
Result unitsMFR in g/10 min; MVR in cc/10 min & melt density (Method B)
Power supply230 V, 50 Hz, single phase (export voltages configurable)
Materials

Polymers tested

All major thermoplastics whose flow temperature falls within the 0–400 °C range:

HDPELDPELLDPEPPPVCPETABSPSPCNylon (PA)POMPMMAEVATPETPU
Standard Accessories

Standard accessories with every MFI tester

Supplied as standard:

OrificePistonSpoonSpannerPlumb lineFunnelMaterial chargerMirrorTweezerOrifice cleanerBarrel cleanerSample cutterAccessory stand
Applications

Where it's used

Raw material QCVerify incoming polymer granules against supplier specification.
Batch consistencyCheck batch-to-batch consistency during compounding.
Recycled plasticsTest regrind and recyclate before it enters production.
Grade identificationIdentify the grade of unknown thermoplastics.
Process controlInjection, blow moulding, film and pipe extrusion.
R&DEvaluate new polymer formulations and additives.
Standards

Standards covered

Every MFI tester complies with ASTM D1238 and ISO 1133, plus IS 2530 and IS 10810 for Indian standards, and is supplied with a traceable calibration certificate. Method A measures Melt Flow Rate (MFR) by cutting and weighing the extrudate; Method B adds Melt Volume Rate (MVR) and melt density via a piston-travel sensor.

FAQ

Frequently asked questions

What is the difference between Test Method A and Test Method B of ASTM D1238?
Method A measures Melt Flow Rate (MFR) by cutting the extruded polymer at fixed intervals and weighing it — best for polymers below 50 g/10 min. Method B uses a piston-travel displacement sensor to calculate Melt Volume Rate (MVR) and melt density — required above 50 g/10 min. Our Computerized (Method A & B) model supports both in one instrument.
Which MFI tester model should I buy for my plant?
For a small QC lab, the manual KAYJAY/2005/CE is the most economical. For continuous production QC, the KAYJAY/2006/AC with motorised auto-cutting. For R&D or a wide MFI range, the Computerized (Method A & B) measures MFR, MVR and melt density together.
What is the temperature range of your MFI tester?
All models operate from ambient to 400 °C with 0.1 °C resolution and ±0.1 °C accuracy, controlled by a microprocessor auto-tuned PID controller.
Do you provide installation, training and calibration?
Yes — free online installation and on-site operator training as per contract, a calibration certificate with every machine, and annual calibration visits for long-term support.
Which polymers can be tested?
All major thermoplastics — HDPE, LDPE, LLDPE, PP, PVC, PET, ABS, PS, PC, Nylon (PA), POM, PMMA, EVA, TPE, TPU and most engineering plastics — provided their flow temperature stays within the 0–400 °C range.
What is included as standard accessories?
Orifice, piston, spoon, spanner, plumb line, funnel, material charger, mirror, tweezer, orifice cleaner, barrel cleaner, sample cutter and accessory stand.
Get Started

Ready to specify your Melt Flow Index Tester (MFI)?

Send your material, test standard and throughput. We'll respond within one business day with a configuration and quote.

Request a Quote